How to run X and Z reports (Day and Period-to-Date) (SAM4s SPS-320 / SPS-340 / SPS-345)

How to run X and Z reports (Day and Period-to-Date) (SAM4s SPS-320 / SPS-340 / SPS-345)

Use this when: you need today's totals or need to close out the day or period.

Models: SAM4s SPS-320 and SPS-340 (flat keyboard) and SPS-345 (raised keyboard). Manual: CRS Sam4s SPS-300 Operators-Programming Manual v1.76 (crs-usa.com). Applies to firmware v2.018, v02.026 and v02.034; the steps are the same on all three.

Key names: SPS-320/340 subtotal = SBTL, cash = CASH. SPS-345 subtotal = SUBTOTAL, cash = CASH TEND. Both have CLEAR, YES/NO, PAGE UP, PAGE DOWN, X/TIME, FUNC LOOKUP 1/2. (Manual v1.76 p. 28–29.)

Steps

X = read only (totals stay). Z = read and reset to zero (end of day).

JCR sets up a Day report key and a Period-to-Date report key on most registers. Use those: 1. Turn the Mode Switch to X (to look) or Z (to close out). Use the Z key for both. 2. Press the Day report key JCR set up for today's totals, or the Period-to-Date report key JCR set up for totals since the last period reset. 3. Turn the Mode Switch back to REG.

If your register does not have these keys, contact JCR Systems.

If the register asks for a cash count first: 1. Turn the Mode Switch to X with the Z key and press 2 (DECLARATION). The drawer opens. 2. Type the cash total and press the cash key. (You can count coins with X/TIME: e.g. 37 X/TIME 25 then the cash key.) 3. Type the check total and press CHECK. 4. Type each charge total and press the matching CHARGE key. 5. Press the cash key again to finish. The screen shows INPUT AMT, DRAWER TTL and the DIFFERENCE. Then run the report.

When it worked: The report prints. A Z report resets the totals; the report counter goes up by one.

Source: Manual v1.76: X Reports p. 98; Z Reports p. 108; Declaration p. 101; Keyboards p. 28–29.