How to run your daily sales report (X and Z) (SAM4s ER-940 / ER-945)

How to run your daily sales report (X and Z) (SAM4s ER-940 / ER-945)

Use this when: you want to see today's sales (X) or close out the day and reset totals (Z).

Models: SAM4s ER-940 (flat keyboard) and ER-945 (raised keyboard). Manual: CRS Sam4s ER-900E Series Operator and Programming Manual v1.82 (crs-usa.com). Applies to all firmware covered by v1.82 (v1.126 and v2.x) unless a version section says otherwise.

Key names: ER-940 subtotal = SBTL, cash = CASH. ER-945 subtotal = SUBTOTAL, cash = CASH TEND. (Manual v1.82 p. 21–22.)

Steps

X = read only (totals stay). Z = read and reset to zero (end of day).

JCR sets up a Day report key and a Period-to-Date report key on most registers. Use those: 1. Turn the Mode Switch to X (to look) or Z (to close out). 2. Press the Day report key JCR set up for today's totals, or the Period-to-Date report key JCR set up for totals since the last period reset. 3. Turn the Mode Switch back to REG.

If your register does not have these keys, contact JCR Systems.

If the register asks for a cash count first (REQ. DECLARATION): 1. With the switch still in X or Z, press 9, 0, then the subtotal key. 2. Type the cash total and press the cash key. 3. Type the check total and press CHECK. 4. Type the charge total and press the matching CHARGE key. 5. Press the cash key to total the count, then run the report.

If your register uses pop-up clerks, sign a clerk on in REG before running reports.

When it worked: The report prints. A Z report resets the daily totals; the Z counter goes up by one.

Source: Manual v1.82: X Reports p. 96; Z Reports p. 97; Running Reports p. 102; Macro keys p. 44; Cash Declaration p. 103.